3321

3321

Menu driven, sealed, backlit, conductivity controller with 2 relays and tinned lead connectors.

Add this item to your custom quote page by clicking the above "add to quote" button.

Description

Conductivity, resistivity, temperature in-line controller. 1/8 DIN, RoHS compliant, with 2 sets of programmable on/off relays and backlight. Extremely price competitive.

  • Easy to install 1/8 DIN plastic casing.
  • Clear LCD displays conductivity, resistivity or temperature with backlight.
  • Universal power supply input from 100 to 240 V AC.
  • Automatic or manual temperature compensation.
  • Two sets of programmable on/off relays for conductivity or resistivity.
  • RoHS, CE compliant.

Specifications

Conductivity / Resistivity Range K=0.01-1 cm Range 1
0.000 to 1.999 uS/cm / 0.00 to 19.99 MΩ
Conductivity / Resistivity Resolution K=0.01-1 cm Range 1
0.001 uS/cm / 0.01 MΩ
Conductivity / Resistivity Accuracy K=0.01-1 cm Range 1
±0.5% F.S. ±1 digit
Conductivity / Resistivity Range K=0.01-1 cm Range 2
0.00 to 19.99 uS/cm / 0.000 to 1.999 MΩ
Conductivity / Resistivity Resolution K=0.01-1 cm Range 2
0.01 uS/cm / 0.001 MΩ
Conductivity / Resistivity Accuracy K=0.01-1 cm Range 2
±0.5% F.S. ±1 digit
Conductivity Range K=0.1-1 cm Range 1
0.00 to 19.99 uS/cm
Conductivity Resolution K=0.1-1cm Range 1
0.01 uS/cm
Conductivity Accuracy K=0.1-1 cm Range 1
±0.5% F.S. ±1 digit
Conductivity Range K=0.1-1 cm Range 2
0.0 to 199.9 uS/cm
Conductivity Resolution K=0.1-1cm Range 2
0.1 uS/cm
Conductivity Accuracy K=0.1-1 cm Range 2
±0.5% F.S. ±1 digit
Conductivity Range K=1.0-1 cm Range 1
0.0 to 199.9 uS/cm
Conductivity Resolution K=1.0-1cm Range 1
0.1 uS/cm
Conductivity Accuracy K=1.0-1 cm Range 1
±0.5% F.S. ± 1 digit
Conductivity Range K=1.0-1 cm Range 2
0 to 1999 uS/cm
Conductivity Resolution K=1.0-1cm Range 2
1 uS/cm
Conductivity Accuracy K=1.0-1 cm Range 2
±0.5% F.S. ±1 digit
Conductivity Range K=1.0-1 cm Range 3
0.00 to 19.99 mS/cm
Conductivity Resolution K=1.0-1cm Range 3
0.01 mS/cm
Conductivity Accuracy K=1.0-1 cm Range 3
±0.5% F.S. ±1 digit
Temperature Range
-10.0 to 120.0 °C
Temperature Resolution
0.1 °C
Temperature Accuracy
±0.3 °C
Temperature Compensation
Manual/Auto -10.0 to 120.0 °C (Thermistor,10K ohm at 25.0 °C)
Cell Constant
0.01, 0.1, 1.0-1 cm, 2 wire
Reference Temperature
25.0 °C, factory set
Temperature Coefficient
2.00 or 0.00 %, user selectable
Control Type/Relay Output
2 ON/OFF controls / 5 A at 115 V AC or 2.5 A at 220 V AC, resistive load only
Display
LCD with backlighting
Power
100 to 240 V AC at 50/60 Hz
Ambient Temperature Range
From 0 to 50 °C
Case
1/8 DIN case, 90 mm depth

Documentation and Supports