Description
Jenco EC3175 is a new conductivity meter with temperature readout, backlit LCD display, selectable cell constant and a streamlined look.This benchtop meter is RoHS compliant.
- Clear, large LCD display with backlight
- Displays Conductivity/TDS and temperature at same time
- Accepts 2-wire conductivity cells with adjustable k=0.01, k=0.1, k=1 and k=10 cell constants for improved flexibility and accuracy
- Convenient one point calibration
- Calibration data is stored in memory and is ready for use on power up
- Automatically selects one of three conductivity ranges to display readings
- Readings are automatically compensated for temperature (ATC)
- Meter automatically switches into manual compensation when temperature probe is not present
- Intuitive operation with membrane keypad with tactile and audio feedback.
- Splash resistant case is made with durable, reinforced plastic for added protection. protective covers for connectors are included
- Smaller case does not clutter valuable desk space
- 8pin DIN connector for conductivity cell & 10k thermistor
- AC adaptor or battery power
Specifications
Conductivity/TDS Range K=0.01
0.000 uS/cm to 19.99 uS/cm / 0.000 mg/L to 19.99 mg/L
Conductivity/TDS Resolution K=0.01
0.001 uS/cm ; 0.01 uS/cm / 0.001 mg/L ; 0.01 mg/L
Conductivity/TDS Accuracy K=0.01
±0.5% F.S.
Conductivity/TDS Range K=0.1
0.00 uS/cm to 199.9 uS/cm / 0.00 mg/L to 199.9 mg/L
Conductivity/TDS Resolution K=0.1
0.01 uS/cm ; 0.1uS/cm / 0.01 mg/L ; 0.1mg/L
Conductivity/TDS Accuracy K=0.1
±0.5% F.S.
Conductivity/TDS Range K=1
0.0 uS/cm to 19.99 mS/cm / 0.0 mg/L to 19.99 g/L
Conductivity/TDS Resolution K=1
0.1 uS/cm ; 1 uS/cm ; 0.01 mS/cm / 0.1 mg/L ; 1 mg/L ; 0.01 g/L
Conductivity/TDS Accuracy K=1
± 0.5% F.S.
Conductivity/TDS Range K=10
0 uS/cm to 199.9 mS/cm / 0 mg/L to 199.9 g/L
Conductivity/TDS Resolution K=10
1 uS/cm ; 0.01 mS/cm ; 0.1 mS/cm / 1 mg/L ; 0.01 g/L ; 0.1 g/L
Conductivity/TDS Accuracy K=10
± 0.5% F.S.
Temperature Range
0.0 to 100.0 °C
Temperature Resolution
0.1 °C
Temperature Accuracy
±0.2 °C
Reference Temperature
15.0 to 25.0 °C, default 25.0 ℃
Temperature Coefficient
0.00 to 4.00%, default 1.91%
TDS Factor
0.30 ~ 1.00, default 0.65
Basic Cell Constant
K=0.01, K=0.1, k=1.0 or k=10, user selectable
Power Supply
100 ~ 240 VAC adapter or AAA x 6
Calibration Backup
Yes
Audio Feedback
All touch keys
Auto Ranging
Yes
Ambient Temperature Range
0 to 50 °C
ATC Probe
Thermistor, 10k ohm
Dimensions (w x d x h )
150 x 203 x 72 mm
Weight
504 grams (excluding batteries)